Exit Code 3010 Sccm

Initially, we hosted PowerShell inside an AppDomain and invoked a pipeline. This post describes the return codes that SCCM understands for Package and Program deployments and shows which codes are classed success, reboot, or retry. Post questions here that are appropriate for the operating system deployment feature of Configuration Manager 2012. exe, but things quickly got messy, so I switched to trusty old WMI, but managed using PowerShell and SCCM of course :) I’ve tried to break it down into sections. Many times it involves a result code of "3010". I'm currently creating a package for SCCM that is wrapped using PowerShell. After this it exits with exit code 3010 telling the Config Mgr client that reboot is required. xml ” and past in “ Visio. Please be aware that the BIOS Update may run several minutes and may show a black screen for about a minute depending on the hardware platform. Imaginen que por ejemplo quieran crear 2 planes de ahorro de energia dependiendo si es por la mañana o si es por la tarde. He developed a strong knowledge of SCCM and MDT to build automated OS deployment solution for clients, managed large and complexe environment, including Point of Sale (POS) related projects. An exit code of -3 is considered a failure. ConfigMgr will then take care of the reboot when needed. Available beginning with Windows Installer version 4. We also have no. Online resources. your doing great work Please keep up this good work. Post questions here that are appropriate for the operating system deployment feature of Configuration Manager 2012. log, there was an application that installed silently without any reboot (Matched exit code 3010 to a PendingSoftReboot entry in exit codes table. Quit the current batch script, quit the current subroutine or quit the command processor (CMD. Note : If you are prompted with a Security dialog box about removing explicitly defined permissions, click Yes. SCCM Task Sequence And Program Behavior Are task sequences subject to the actions you set for the program, such as normal, hidden, restart after running, etc? I know they show the task sequence progress bar, but will the program run hidden all the time with just that bar visible?Jason, I. exe is actually built-in in SCCM, there is no need to download separate toolkits for it. using SCCM package. If you have a process where you want to manually Exit the Script and trigger an SCCM "Soft Reboot", it does not work. Darryl Miles, IT guy from Down Under Home YouTube About « Setting up IBM Endpoint Manager, Software Usage Analysis (SUA) 1. For information on the exit codes in this case, see step 3 in Installing Using the Silent Mode. An uncaught THROW will set the exitcode to 1. [1] Out of range exit values can result in unexpected exit codes. 20 PackageShare Path (32bit): "{Packageshare}\installers\7zip\7z920. at Wednesday, April 14, 2010 Labels: MY Notes , SCCM 2007. Reboot exit codes vary between executable installers. For example the "3010" exit code means there is a "Soft Reboot" required. As result of this exit code, the task sequence decides to insert a reboot with default values (60 secondes delay). This post describes the return codes that SCCM understands for Package and Program deployments and shows which codes are classed success, reboot, or retry. The download for KB2882125 contains an msi that has to be installed on the primary site(s). 2 (min version) but in detection method. It also write the name of the product to the detection key and the exit code of that uninstall (use full for troubleshooting). I believe it to be a problem with Microsoft's patch detection. This template can also be used for stand-alone installations (without using SCCM or MDT)! An SCCM package is basically a container with source files. Tips and tricks for beginners SCCM admins G. Stainless steel construction 0 to 525 sccm Precise linear control flow rate Suitable for all dry non-corrosive gases compatible with materials Description: The Piezoelectric Gas Flow Valve Model PEV-1 is a high precision gas leak valve which uses a piezoelectric bender element that responds directly to a voltage signal, which causes the opening. We will try to get the 3010 return code implemented. When I manually run one of the affected patches on the client, it indicates the patch is not required and exits with return code 17025. I've tried various versions of "Exit-Script -ExitCode 3010" with -AllowR. on machines that failed to take them through SCCM. Posted by Ben Lee | Sep 4, Repeat for the "Success Pending reboot codes" (3010) exit code = -2147023293. 32 can be found on the SCCM site server, under "\tools\" folder. Here some usefull information about GINA(. If you have a process where you want to manually Exit the Script and trigger an SCCM "Soft Reboot", it does not work. Chocolatey is software management automation for Windows that wraps installers, executables, zips, and scripts into compiled packages. Enterprise Software Thread, Using Robocopy as an SCCM 2012 package Reporting back as failed when it hasn't in Technical; Hi, I wish to create an SCCM package that will copy down some. My package will return 3010 - reboot required when the script is finished. Check ram with call a belkin wireless N1 file sharing in XP. Symantec helps consumers and organizations secure and manage their information-driven world. 66), bei einem User, der "Exit Code 259" aufgetreten. WW " Folder. Allposts inthis website are the property of PaddyMaddy &maynotbe reused inanyway without approval. When we look at the SMS/SCCM console collection, there is an entry for the client status that indicates either Yes or No. I am in the vcenter 6. The exit code is shown in the report for this task sequence but I don't know how to handle this with wmi. We have created our own customized AdobeReader 9. Could you help with a vbscript to return 3010 once setup is finished. Minimal ITunes installation 11. *** Dim WSHShell. I know I can define success exit codes. code in the first instance. This is a problem if installing in a task sequence as a reboot will be forced even if you supress the reboot. When succesfull to\\server\share\success\computername, when failed to \\server\share\failed\computername It then also sends a mail with location of logfiles. Designed for version 9. You can have all kinds of system. #soft reboot <- will not 'force' restart, and sccm will progress past, but will nag to restart afterward. Online resources. Handles SCCM exit codes, including time sensitive dialogs supporting SCCM's Fast Retry feature - providing more accurate SCCM Reporting (no more Failed due to timeout errors). Nick has been awarded in 2016 as a Microsoft MVP in Enterprise Mobility category. Configure HP Bios during OSD. Return a custom exit code Exit-Script -ExitCode 69004 #this code to indicate a reboot is pending on this machine, and installation cannot proceed. Could you help with a vbscript to return 3010 once setup is finished. Copy in this folder this files and folders: 3010: A reboot is required to. 2 The same was in the beginning with God. Create " SilentUninstallConfig. Configure HP Bios during OSD. List of all predefined SMS/SCCM Exit-Codes: A retry exit code will force SMS/SCCM to rerun the advertisement after a timeout of 10 minutes. As a result of this the user is sometimes presented with a reboot prompt with a countdown timer (the default is 5 minutes in SCCM 2007) due to the installation returning a 3010 exit code. Exit Codes When installing from SMS/SCCM, you can add the "/m" parameter to send notification of the execution result with a MIF file. I think i am missing something. Creative Cloud applications store information about the installation and launch process in log files. Along with Office 2016, Microsoft has released office 2016 deployment tool. I'm not even checking return codes between install parts, but if you want some sort of control, you should check that a return code after any given command is either 0 or 3010 (3010 is being cleaned up by the reg file that I'll attach too). Try reinstalling your Adobe application. Returning an exit code from a PowerShell script seems easy… but it isn’t that obvious. Download and extract the PSP/SPP files or hp\swpackages folder from SPP into a directory on the Deployment Server express share, for example ws6-x64-psp or ws6-x64-spp. exe" | find " 11. SCCM 2012 : "Another Installation is already in Progress" when deploying Applications thru OSD deployment. The first code snippet is the PowerShell script. The reason for sending the mail is that the SCCM task sequence cannot finish properly and keeps hanging in the In Progress state. About Greg Ramsey Greg Ramsey is a systems engineer specializing in global systems management for Dell IT. Part 2 of the Silverlight Deployment Guide describes the processes that are used to deploy Silverlight. Changes will not be effective until the system is rebooted. exe? How can I get more verbose debugging information? My task worked at first, but then it stopped after a couple days. Note : If you are prompted with a Security dialog box about removing explicitly defined permissions, click Yes. Return Code 3010 -> Neustart). Powered by Blogger. Online resources. Retval=0 ' *** Install Application. What does SCCM by default is to run a 64-bit installer with the 64-bit paths and a 32-bit installer with the 32-bit paths. Reboot exit codes vary between executable installers. Sure, When I check the app in the Control Panel-->Programs and Features, That is what was listed after an MSI only install. Just to clarify, we use this script with the legacy version of Windows up to Windows Server 2016 (build 1607) and Windows 10 (build 1607). Add the -exporttowmiswitch to the command line to have TI record the data here. When you run "Start-Process" you can capture the exit code when you assign it to a variable with the "-wait" switch included. What I am trying to do is make a one-step deployment in SCCM where I install an MSI and then after the install is done, copy a license file to a folder that was created during the MSI install. I'm using an SCCM 2012 application deployment to install software. Run DOS / Cmd command Action events (68000, 68002, 68202, 68402) and Start program / application Action events (67000, 67002, 67202, 67402) may end with errorlevels or exit codes, that indicate the termination status of executed Command or Application. ) So the application doesn't have any force reboot option and for sure,something else is caused the reboot. There are many reasons why Error 0x103259 Sccm happen, including having malware, spyware, or programs not installing properly. Subsequent to this post’s initial publication, I completed all of the application packages and task sequences for my Office 2016 series, and I discovered in testing that the. Configure HP Bios during OSD. If an application package is written internally to perform a restart, there is not a way to prevent it. However these sometimes exit with a code of 3010 (soft-reboot). Utilizando esta consulta, todas la máquinas se agregarán a esta colección desde las 8AM hasta las 3PM. 0 the instructions there or a video card? I have researched and bang for the buck, although a trouble shooter. best, Oliver. For a full list of other possible codes see the post "SCCM Package Success, Reboot and Retry Return Codes". This script will give us very handy the right click list in of all collection membership of particular computer. biospassword1. SCCM Recognized Return Codes By Mike in Enterprise Computing , Windows on Monday, January 30, 2012. If your organization is supporting multiple versions of Office, remember to put the necessary exclusions in SCCM so if any user or machine receives Office 365; the older versions of office do not get installed. PowerShell Logging – Capturing the Exit Code. There are normally 2 reason why a reboot would take place during a running task sequence - when an application, that is being installed as part of an Install Software task sequence step, returns a 3010 exit code or when you specifically use a Restart Computer task sequence step. 3 Installation citrix web Crystal Reports 2011 custom signed drivers DpInst dpinst exit codes dpinst return codes ENABLE_DYNAMIC_CLIENT_NAME ENABLE_SSON exit code how to install WDK how to sign a driver ICA Client ICAWebWrapper. thanks and regards Madhu R. If 3010 is passed back to SCCM, a reboot prompt will be triggered. Preventing Task Sequence Reboot After Software Install which produces a 3010 exit code So some apps like IE8 return an exit code of 3010 upon installation completion. What does return code 1 mean for cmd. Configure HP Bios during OSD. Subsequent to this post’s initial publication, I completed all of the application packages and task sequences for my Office 2016 series, and I discovered in testing that the. If you copy an MBR Video Card also known to Service Pack 3? When I installed the Exit Code (RX-580) and it is not router for 4 pc's. A semiconductor power device includes a drift region of a first conductivity type, a well region extending above the drift region and having a second conductivity type opposite the first conductivity. Then it uses SCCM's built in reboot warnings and timers that you have built. After running ccmclean. LifeAsBob : Wednesday, October 16, 2019. Please be aware that the BIOS Update may run several minutes and may show a black screen for about a minute depending on the hardware platform. I'm trying to detect. At this point it hard to determine the actual cause. In the Microsoft Office Customization Tool wizard, you can customize almost all available settings, but in this example, I’ll only configure a few of these settings, to make the installation unattended, and to provide a simple user experience to users, when they install Office 2013 from the System Center 2012 Application Catalog. If 3010 is passed back to SCCM, a reboot prompt will be triggered. Stores the return code that was returned by the last action that was run. SCCM 2012 : "Another Installation is already in Progress" when deploying Applications thru OSD deployment. 2 The same was in the beginning with God. This is a problem if installing in a task sequence as a reboot will be forced even if you supress the reboot. TRying to upgrade BIOS via commandline (SCCM) We created a distrbution that upgrades the BIOS firmware using "HPQFLASH. Clients report "Failed" status on packages which uninstall a product, when it turns out the product was not installed to begin with. ) So the application doesn't have any force reboot option and for sure,something else is caused the reboot. Keeping in mind that SCCM Application Installs will still use MSiExec or InstallShield 1641 is the "hard reboot, don't do anything else" reboot exit code, which i. This tool will help administrators. For example the “3010” exit code means there is a “Soft Reboot” required. I recommend using a wrapper (a script) to execute the installation files and for any configuration you may need. This Exit Codes or Return Values can be retrieved from PowerShell App Deployment Toolkit. 2250*) A retry exit code will force SMS/SCCM to rerun the advertisement after a timeout of 10 minutes. When I manually run one of the affected patches on the client, it indicates the patch is not required and exits with return code 17025. After this it exits with exit code 3010 telling the Config Mgr client that reboot is required. Try leaving -PassThru off the Execute-MSI cmdlet. >>>CLICK HERE<<< What I am trying to do is add a line of code that will kick back a text file. PSMDTAG:FAQ: How can my script control the PowerShell exit code? Answers: 1. On the return codes tab, change the code type (action) for the return code 3010 from restart to Success (no reboot). Scripts Thread, Script with Exit Code options SCCM in Coding and Web Development; Hi, I want to make a script that will do something different depending on the edit code A. Some System Center Configuration Manager (SCCM) recognized return codes:. Just to clarify, we use this script with the legacy version of Windows up to Windows Server 2016 (build 1607) and Windows 10 (build 1607). What I am trying to do is make a one-step deployment in SCCM where I install an MSI and then after the install is done, copy a license file to a folder that was created during the MSI install. The second app exit code 0 was returned to task sequence instead of 3010. This scenario is when a Program is deployed to a machine running the full operating system and SCCM client. If you are not finding this to be true in your situation, it is recommended to open a ticket with Technical Support. I'm trying to detect. Available Deployment. It works 3 out of 4 times. Alert: Modules fail to load or "Antivirus Protection is Nonfunctional" ESET message received on 32-bit systems after upgrading to Windows 10 version 1803. Ability to prevent reboot codes (3010) from being passed back to SCCM, which would cause a reboot prompt. Internet Explorer 10 fails to install As I am still running Windows 7 simply due to the lack of time to update my main computer, beeing able to update to to Internet Explorer 10 was simply a great opportunity to improve my experience on browsing the web. What am I missing? Does TSManager maybe check for both a 3010 plus the "reboot required" registry value or something?. Allposts inthis website are the property of PaddyMaddy &maynotbe reused inanyway without approval. ERROR_ROLLBACK_DISABLED: 1653. System administrator tools make it easy to inventory and send silent installs and updates to computers in your network. Altiris Error Code 3010 The 1603 error is an MSI error code indicating a failure that is generic, but computer-specific. Hi We are evaluating the new unknown computer support in SCCM 2007 R2. *** Dim WSHShell. Christian Fosund Christian is a senior consultant and MCT, specialized in the products System Center Configuration Manager and Microsoft Deployment Toolkit, and has been responsible for design and implementation of complex environments, spread geographically throughout the world. log the only differences that i can see between the two attempts in the Session ID. this process using "SCCM Client Centre" or the "Right click. Hi bbithelpdesk, Thanks for posting back. If SMS cannot find or correlate any installation status Management Information Format (MIF) files for the program, it uses the program's exit code to determine status. This Exit Codes or Return Values can be retrieved from an MSI Setup. Ok, so here is the short( not really sure this is going to be short by the way, well nothing is perfect) story, once again a customer (Thank you Bill for letting me test fun stuff in your environment!) asked me for a feature that I have done multiple times before, so the task was easy, just upgrade. I've also seen that with a number of Office patches. That exit code is not produced by BatchPatch but rather by the remote uninstaller. The intermediate state (IS) of type-I superconductors (SC) has recently became a topic of increasing interest [1,2]. best, Oliver. Anything other than exit code 0 is usually a failure (MSIs usually return exit code 3010 to indicate a reboot). Hi We are evaluating the new unknown computer support in SCCM 2007 R2. Exit-Script -ExitCode 69002 #this code to indicate user clicked to install PowerShell later. Citrix is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement by Citrix of the linked Web site. ENS fails to properly install if user access to the user temp folder is restricted. Describes the return codes that SCCM understands for Package and Program deployments and shows which codes are classed success, reboot, or retry. " Hard reboot just prevents other software from installing until the reboot occurs however it normally. Due to the nature of information and technical data which can change without notice and are beyond our control, we expressly disclaim any and all liability on reliance of the information presented. It keeps coming with tried a different exit code 3010 sccm xp i haven't decided. However these sometimes exit with a code of 3010 (soft-reboot). Attached are links to both the PS1 file and the log files (both install log files that get created). on machines that failed to take them through SCCM. Hier ein Beispielcode dazu:. Preventing Task Sequence Reboot After Software Install which produces a 3010 exit code So some apps like IE8 return an exit code of 3010 upon installation completion. Reboot of machine "%1" is needed to complete the configuration of IIS component of operating system. 3013 The printer driver is known to be unreliable. I have found that I prefer to run a package or application that is just a VBS script (though you could use others) that runs and only does a return code of 3010 (reboot needed). Contributor of System Center Dudes. Windows PowerShell Exit Codes. 5 redistributable program indicate whether setup has succeeded or failed: 0 - Setup completed successfully. 3010 - Setup completed successfully; a system restart is required. Replied to a forums thread Program exit code 3010 but Task Sequence not initiating a reboot in the Configuration Manager Software Distribution Forum. exe Return Values and Run-Time Errors (Basic MSI and InstallScript MSI Projects) ANSI code page for is not installed on the system and therefore. We have no issues with adding. What is Active Setup? Active setup is a process that runs automatically when a user logs in. In this blog post I will show you an approach that works for PowerShell scripts that can be called from both PowerShell and batch scripts, where the command to be executed can be specified in a string, execute. NET Framework 4. After this it exits with exit code 3010 telling the Config Mgr client that reboot is required. It works 3 out of 4 times. Wrapping is automatic, not explicit, so be careful with unwrapping if you plan to use them for your own tests. Could you help with a vbscript to return 3010 once setup is finished. I'm currently creating a package for SCCM that is wrapped using PowerShell. Working with the restart behavior of Applications in ConfigMgr 2012 October 12, 2015 February 17, 2013 by Peter van der Woude This week I will do a small post about working with the restart behavior of installations in combination with the Application Model in ConfigMgr 2012. That can be done later such as next time the PC needs to be imaged they can turn it on manually or via TS (remember the admin password step has to be there first). Anything other than exit code 0 is usually a failure (MSIs usually return exit code 3010 to indicate a reboot). Please contact your Verify. Some System Center Configuration Manager (SCCM) recognized return codes: Success: 0 Failed / Reboot: 1604 1641 3010 3011 Failed / Retry: 4 5 8 13 14 39 51 53 54. Configuration Manager 2007 ; Package install keeps failing with exit code 1619 Sign in to follow this. For a full list of other possible codes see the post “SCCM Package Success, Reboot and Retry Return Codes“. I get the same lower version from opening Chrome and checking "About Google Chrome" I don't know why it is like that but I usually pull the version from the uninstall key, so that's why I have it listed as that version. Then it uses SCCM’s built in reboot warnings and timers that you have built. From appenforce. Install shield exit code -2147213312 , SCCM package. This means the PC will reboot and the user cannot defer it (bad). Describes the return codes that SCCM understands for Package and Program deployments and shows which codes are classed success, reboot, or retry. Installing KB2882125 on the siteserver creates a new ConfigMgr package though and that one is intended to be installed on the clients!. For information on the exit codes in this case, see step 3 in Installing Using the Silent Mode. When you run "Start-Process" you can capture the exit code when you assign it to a variable with the "-wait" switch included. dll) OSDGINA. 3 Installation citrix web Crystal Reports 2011 custom signed drivers DpInst dpinst exit codes dpinst return codes ENABLE_DYNAMIC_CLIENT_NAME ENABLE_SSON exit code how to install WDK how to sign a driver ICA Client ICAWebWrapper. Full OS – Package & Program. Within System Center Configuration Manager the ability to enable is very simple. Anything other than exit code 0 is usually a failure (MSIs usually return exit code 3010 to indicate a reboot). There are some systems that get the firmware and others that report a return code within the log file of 0x103. Preventing Task Sequence Reboot After Software Install which produces a 3010 exit code So some apps like IE8 return an exit code of 3010 upon installation completion. When deploying Windows 2000, Windows XP, and Windows 2003, OSD installs a custom GINA (OSDGINA. If the PSP is a Delta bundle, then both PSP and the Delta bundle files will need to be combined in the same directory. Distribution Manager installed IIS component of operating system to distribution point "%1". Use this forum for questions on the new System Center 2012 Configuration Manager product technology. Also make sure you are not accidentally forcing a reboot User Experience tab:. This article provides a useful index of MSIEXEC exit codes and what they represent. Then it uses SCCM’s built in reboot warnings and timers that you have built. 1) Create an XML file containing below matter and save as Add_Access. Claus; EXIT /B 3010))) Now you have the files that we should use in the task sequence in SCCM. I bit confuse on execute batch file through SCCM to x64 bit windows 7 and it will return 3010 exit code, but i want to ignore it and the exit code should be 0. Citrix is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement by Citrix of the linked Web site. Exit-Script -ExitCode 1641. As result of this exit code, the task sequence decides to insert a reboot with default values (60 secondes delay). Posts about Uncategorized written by Sri Boddupalli. Direct imaging of type-I SC reveals two distinct topologies of the intermediate state: flux tubes are formed upon magnetic field penetration and laminar patterns appear upon flux exit [2]. exe is actually built-in in SCCM, there is no need to download separate toolkits for it. Exit Code ErrorRamey I P I TD TR TABLE A The exit B command terminates a script just as in a C B program It can also return a value which is available to the script's parent process P A Every command returns an exit status exit code I sometimes referred to as a return status I or exit code I Exit Code - Python A A successful command returns a. The challenge is that if we elected to place this compliance script into a System Center Configuration Manager – Configuration Item script, it could lead to some undefined results. exe use 1000 Full duplex. Jetzt ist bei der Installation der neuesten Putty Version (0. Solution: For more information on the exit code, refer to the documentation for the program you are distributing. When we author SCCM scripts here, we ensure they return the appropriate exit code to ConfigMgr. Import the image in SCCM or MDT After this process you need to import the source content in SCCM. I did finally figure out how to do this with application dependencies but I'd also like to know how to do this with task sequences. Available Deployment. ←Preventing Task Sequence Reboot After Software Install which produces a 3010 exit code. The first code snippet is the PowerShell script. Author Topic: How to return success/failure from a batch file? (Read 180548 times) 0 Members and 1 Guest are viewing this topic. Ok, so here is the short( not really sure this is going to be short by the way, well nothing is perfect) story, once again a customer (Thank you Bill for letting me test fun stuff in your environment!) asked me for a feature that I have done multiple times before, so the task was easy, just upgrade. This article provides a PowerShell scripting template for SCCM and MDT packages. your doing great work Please keep up this good work. I'd prefer SCCM to report success, but I won't bash my head too long. If you have a process where you want to manually Exit the Script and trigger an SCCM "Soft Reboot", it does not work. Cmd Error Code 3010 EXIT. While working on a script that does file copy using Robocopy utility, I had the need to capture the exit code from the process I started. Suggestions for. SCCM will then schedule a proper reboot session and notify the user. If i then open Software center on the client, "retry" the installation, it works fine. Available beginning with Windows Installer version 4. The scanners include 3010 _smstslastactionretcode support your MOBO. The return code from Robocopy is a bit map, defined as follows: Hex Decimal Meaning if set 0×00 0 No errors occurred, and no. If you have a process where you want to manually Exit the Script and trigger an SCCM "Soft Reboot", it does not work. After importing the image in SCCM, add it to the DP’s and check if the image is replicated correctly on all selected. Windows Setup failed with hexadecimal exit code 0x80070241 (decimal 2147942977). A very simple example of this is the following code which could be called from within a task sequence and allow the ts to continue even if the returned retval was 3010: Dim Retval. It works 3 out of 4 times. ConfigMgr will then take care of the reboot when needed. An exit code of -3 is considered a failure. コマンドが成功していれば「0」、エラーで以上終了していれば「0以外」が入っています。この当たりの話を詳しく知りたい方は、「errorlevel(終了コードを取得する) -コマンド別解説-」で詳しい解説を行っていますのでそちらを参考にして下さい。. Enterprise Software Thread, Using Robocopy as an SCCM 2012 package Reporting back as failed when it hasn't in Technical; Hi, I wish to create an SCCM package that will copy down some. exe returns and, in some cases, what to do to fix them. EXE -s -a" and after the install a psshutdown command is issued. If you are not finding this to be true in your situation, it is recommended to open a ticket with Technical Support. exe exitCode Sets the %ERRORLEVEL% to a numeric number. WW " Folder. Technically this has no sense, you have a bundle that contains both 32bit and 64bit. This helps when you need to capture non-failure exit codes. For what ever reason, the SCCM team decided to key a PowerShell script’s success based on the console output. Available Deployment. When we look at the SMS/SCCM console collection, there is an entry for the client status that indicates either Yes or No. Keeping in mind that SCCM Application Installs will still use MSiExec or InstallShield 1641 is the "hard reboot, don't do anything else" reboot exit code, which i. Clients report "Failed" status on packages which are in fact installed properly. For #2 item, when you run TI with the SCAN option the packages that are assessed can be recorded in the new WMI table: root\Lenovo\Lenovo_Updates. That can be done later such as next time the PC needs to be imaged they can turn it on manually or via TS (remember the admin password step has to be there first). Also please ensure that the http(s) traffic is not blocked on this machine by firewall settings. While working on a script that does file copy using Robocopy utility, I had the need to capture the exit code from the process I started. After that (manual) installation went fine again! The following lines were seen in mpsetup. Symantec helps consumers and organizations secure and manage their information-driven world. [1] Out of range exit values can result in unexpected exit codes. The deployment is based on script silently installation. You can have all kinds of system. Re-install. Preventing Task Sequence Reboot After Software Install which produces a 3010 exit code an exit code of 3010 Task-Sequence-Reboot-After-Software-Install-with. How to deploy Office 2016 using SCCM 2012 R2 In this post we will see how to deploy Office 2016 using SCCM 2012 R2. Exit-Codes Wenn Sie ausgehend von SMS/SCCM installieren, können Sie den Parameter "/m" hinzufügen, um eine Benachrichtigung über das Ausführungsergebnis mit einer MIF-Datei zu senden. A very simple example of this is the following code which could be called from within a task sequence and allow the ts to continue even if the returned retval was 3010: Dim Retval. LifeAsBob : Wednesday, October 16, 2019. fine except that once the script is completed I need SCCM 2012 to get a exit code of 3010 so that it would schedule a restart of the PC. Handles SCCM exit codes, including time sensitive dialogs supporting SCCM's Fast Retry feature - providing more accurate SCCM Reporting (no more Failed due to timeout errors). Online resources. His extended experience has been developed through several IT roles, from first-line support to principal consultant, towards a wide range of clients and sectors. Initially, we hosted PowerShell inside an AppDomain and invoked a pipeline. So it appears subinacl. If your organization is supporting multiple versions of Office, remember to put the necessary exclusions in SCCM so if any user or machine receives Office 365; the older versions of office do not get installed. In my organisation only a few members of staff need to have access to the SCCM console, for obvious reasons I want to keep that to a minimum, never too good to let the patients run the asylum. After running ccmclean. In this blog post I will show you an approach that works for PowerShell scripts that can be called from both PowerShell and batch scripts, where the command to be executed can be specified in a string, execute. The log file for the successful pxe boot from the 2003 server shows an exit code of 0 for smstftp. Install shield exit code -2147213312 , SCCM package. I recommend using a wrapper (a script) to execute the installation files and for any configuration you may need. zip format and wh KMDF Related Issues I have seen a strange problem when we target the drivers as software package the installation was never triggered in the Task sequence, When. For example the "3010" exit code means there is a "Soft Reboot" required. Scripts Thread, Script with Exit Code options SCCM in Coding and Web Development; Hi, I want to make a script that will do something different depending on the edit code A. Chocolatey is trusted by businesses to manage software deployments. Mission Impossible Code Part 2: Extreme Multilingual IaC (via Standard Code for Preflight TCP Connect Testing a List of Endpoints in Both Bash and PowerShell) 2019-07-23 CloudFormation Stack Attack.